Review



recombinant human vwfa2 antibody  (R&D Systems)


Bioz Verified Symbol R&D Systems is a verified supplier
Bioz Manufacturer Symbol R&D Systems manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 93

    Structured Review

    R&D Systems recombinant human vwfa2 antibody
    Schematic representation of the working mechanism of the developed biosensor as a point-of-care diagnostic device for the quantification of <t>vWFA2</t> levels.
    Recombinant Human Vwfa2 Antibody, supplied by R&D Systems, used in various techniques. Bioz Stars score: 93/100, based on 2 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/recombinant human vwfa2 antibody/product/R&D Systems
    Average 93 stars, based on 2 article reviews
    recombinant human vwfa2 antibody - by Bioz Stars, 2026-02
    93/100 stars

    Images

    1) Product Images from "Electrochemical Profiling of vWFA2 for Systemic Inflammatory State Detection"

    Article Title: Electrochemical Profiling of vWFA2 for Systemic Inflammatory State Detection

    Journal: ACS Measurement Science Au

    doi: 10.1021/acsmeasuresciau.4c00060

    Schematic representation of the working mechanism of the developed biosensor as a point-of-care diagnostic device for the quantification of vWFA2 levels.
    Figure Legend Snippet: Schematic representation of the working mechanism of the developed biosensor as a point-of-care diagnostic device for the quantification of vWFA2 levels.

    Techniques Used: Diagnostic Assay

    Bode (magnitude) (a), Bode (phase) (b), and Nyquist (c) plots representing impedance measurements at each concentration of vWFA2 in pooled plasma samples.
    Figure Legend Snippet: Bode (magnitude) (a), Bode (phase) (b), and Nyquist (c) plots representing impedance measurements at each concentration of vWFA2 in pooled plasma samples.

    Techniques Used: Concentration Assay

    Biosensor response against cross-reactive molecule (IP-10) in the presence of BSA and vWFA2 at low (a) and high (b) concentrations.
    Figure Legend Snippet: Biosensor response against cross-reactive molecule (IP-10) in the presence of BSA and vWFA2 at low (a) and high (b) concentrations.

    Techniques Used:

    (a, b) Intra-assay variability (left y -axis) and Interassay variability (right y -axis) of the developed biosensor for various concentrations of vWFA2.
    Figure Legend Snippet: (a, b) Intra-assay variability (left y -axis) and Interassay variability (right y -axis) of the developed biosensor for various concentrations of vWFA2.

    Techniques Used: Intra Assay



    Similar Products

    93
    R&D Systems recombinant human vwfa2 antibody
    Schematic representation of the working mechanism of the developed biosensor as a point-of-care diagnostic device for the quantification of <t>vWFA2</t> levels.
    Recombinant Human Vwfa2 Antibody, supplied by R&D Systems, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/recombinant human vwfa2 antibody/product/R&D Systems
    Average 93 stars, based on 1 article reviews
    recombinant human vwfa2 antibody - by Bioz Stars, 2026-02
    93/100 stars
      Buy from Supplier

    Image Search Results


    Schematic representation of the working mechanism of the developed biosensor as a point-of-care diagnostic device for the quantification of vWFA2 levels.

    Journal: ACS Measurement Science Au

    Article Title: Electrochemical Profiling of vWFA2 for Systemic Inflammatory State Detection

    doi: 10.1021/acsmeasuresciau.4c00060

    Figure Lengend Snippet: Schematic representation of the working mechanism of the developed biosensor as a point-of-care diagnostic device for the quantification of vWFA2 levels.

    Article Snippet: A specific recombinant human vWFA2 antibody and protein were purchased from R&D Systems.

    Techniques: Diagnostic Assay

    Bode (magnitude) (a), Bode (phase) (b), and Nyquist (c) plots representing impedance measurements at each concentration of vWFA2 in pooled plasma samples.

    Journal: ACS Measurement Science Au

    Article Title: Electrochemical Profiling of vWFA2 for Systemic Inflammatory State Detection

    doi: 10.1021/acsmeasuresciau.4c00060

    Figure Lengend Snippet: Bode (magnitude) (a), Bode (phase) (b), and Nyquist (c) plots representing impedance measurements at each concentration of vWFA2 in pooled plasma samples.

    Article Snippet: A specific recombinant human vWFA2 antibody and protein were purchased from R&D Systems.

    Techniques: Concentration Assay

    Biosensor response against cross-reactive molecule (IP-10) in the presence of BSA and vWFA2 at low (a) and high (b) concentrations.

    Journal: ACS Measurement Science Au

    Article Title: Electrochemical Profiling of vWFA2 for Systemic Inflammatory State Detection

    doi: 10.1021/acsmeasuresciau.4c00060

    Figure Lengend Snippet: Biosensor response against cross-reactive molecule (IP-10) in the presence of BSA and vWFA2 at low (a) and high (b) concentrations.

    Article Snippet: A specific recombinant human vWFA2 antibody and protein were purchased from R&D Systems.

    Techniques:

    (a, b) Intra-assay variability (left y -axis) and Interassay variability (right y -axis) of the developed biosensor for various concentrations of vWFA2.

    Journal: ACS Measurement Science Au

    Article Title: Electrochemical Profiling of vWFA2 for Systemic Inflammatory State Detection

    doi: 10.1021/acsmeasuresciau.4c00060

    Figure Lengend Snippet: (a, b) Intra-assay variability (left y -axis) and Interassay variability (right y -axis) of the developed biosensor for various concentrations of vWFA2.

    Article Snippet: A specific recombinant human vWFA2 antibody and protein were purchased from R&D Systems.

    Techniques: Intra Assay